Panasonic KX-TDA

Connection: CSTA Panasonic KX-TDA
Driver required: Included
Firewall ports required: TCP: 33333 and 33334
Firmware version required:
(for new installations)
KX-TDA: 5.0022 (IP-Gateway: 1.401)
Connection requirements: Network card
Other notes: On the TDA15 and TDA30, an IP-Gateway is required. On the other models a CTI Link card is required
Directory download: Extensions

 

Architecture

The Panasonic connects to the LAN via the RJ45 socket on the main unit. The local IP address and other network settings are set through the programming software.

Go Connect Server Installation Notes

To perform an installation you will need the IP address of the PBX.

Advisories

Only one CTI application be connected directly at a time to the Panasonic. To connect more than one CTI application the Panasonic Multiplexer (MUX) is required. This is licensed separately. Go Connect Server detects “connected” handsets to prevent downloading too many devices. If unconnected devices are required they can be added manually.